Stripsal NE
APPLICATIONS: An immersion chemical stripping salt for electroplated deposits of nickel, copper or silver from steel components. No significant attack on basic metal.
OPERATING CONDITIONS: Use 175 gm/l, at 75 to 80°C.
Stripsal NMP / NML
APPLICATIONS: An immersion chemical stripping process for electroplated deposits of nickel, from steel components. No significant attack on basic metal.
OPERATING CONDITIONS: Use Stripsal NML – 200 ml/l + Stripsal NMP – 150 gm/l, at 55 to 65°C, pH>7.
Brisol SS
APPLICATIONS: Electro brightening solution for SS. Produces excellent mirror finish on SS surfaces.
OPERATING CONDITIONS: Use Brisol SS, ready to use solution, at 71 to 95°C, immerse for 4 to 10 minutes, with CCD 27 to 48 A/dm2, 6 to 15 volts.
Brisol HC
APPLICATIONS: Electro brightening solution for high carbon steel and 400 series stainless steel.
OPERATING CONDITIONS: Use Brisol HC, ready to use solution, at 71 to 95°C, immerse for 4 to 10 minutes, with CCD 30 to 60 A/dm2, 8 to 20 volts.
Brisol AL
APPLICATIONS: Electro brightening solution for aluminium and aluminium alloys.
OPERATING CONDITIONS: Use Brisol AL, ready to use solution, at 60 to 65°C, immerse for 4 to 10 minutes, with CCD 9 to 12 A/dm2, 14 to 16 volts.
Brisol CA
APPLICATIONS: Chemical brightening solution for aluminium.
OPERATING CONDITIONS: Use Brisol CA, ready to use solution, at 95 to 105°C, immerse for 0.5 to 3 minutes.
Brisol NF
APPLICATIONS: Electro brightening solution for non-ferrous material like copper and brass.
OPERATING CONDITIONS: Use Brisol NF, ready to use solution, at 15 to 25°C, immerse for 5 to 15 minutes, with CCD 5 to 10 A/dm2, 4 to 10 volts.